Leading companies usually have several advantages, such as pricing power, brand recognition and a loyal customer base. It takes time to achieve a dominant position in an industry, and maintaining that leadership position is an ongoing effort. Small businesses should first aspire to lead their respective local markets before planning for worldwide industry domination.

Din Type Lv Outdoor Feeder Pillar with Real-time Load Reading Facilities

Description 800Amps 1600Amps

Rated Voltage #50Hz;

  1. Phase to Phase

  2. Phase to Earth


415V

240V

Rated Insulation Level:

  1. Voltage

  2. One minute Power Freq. Withstand Voltage

500V

2500V

Rated Short time Current withstand for 3 seconds


31.5ka for 3s

Normal Current Rating (Amps):

  1. Bustars

  2. Incomer-2000 Amp Rated NH3 Disconnector Unit.The Vertical Three Phase Single Pole Operated Disconnector

  3. Outgoing 400 Amp NH Size 2 Vertical (3) Phase) Fuse Switch Disconnector Units

800A


1 x 2000A


5 x 400A

1600A


1 x 2000A


8 x 400A

Framework:

  1. Material and type of Finah

  2. Thickness

  3. Colour

Electro- Galvanized Metal

2.5MM & 3MM

Grey,Red,Blue

Dimension of Feeder Pilla:

  1. Width x Depth x Height (mm) Material and Dimension of Buster (mm)

  2. Material of Busbar

  3. Phase Busburs

  4. Neutral Busbars

  5. Earth Bar

 

1040 x 450 x 1700

Capper

40 x 10

40 x 10

32 x 6

 

1360 x 450 x 1700

Capper

80 x 10

80 x 10

32 x 6

Outgoing Fuse Switch Disconnector Unit:

  1. Type [NH size Rating 400A

  2. Spacing for the outgoing Fuse Switch Disconnector unit (110mm)

  3. Fuse Switch Disconnector contact

    -Material

    -Nos of Spring

 

NH2, 400A

110mm

Stainless Steel

2

Digital meter module and CT:

  1. CT rated 400/5 or 400/1 and of minimum Class 1 for each phase or each outgoing

  2. Mears provided for voltage measurement of at least each phase (R. Y. B) of the main busbars

  3. Digital meter module for on-site load reading,display and data storage shall comply to section 5.4

  4. Digital meter module shall be able to communicate to a data server using standard protocol

  5. Modem module shall be provided

 

400/5A,Class 1

Provided

Comply tp Section 5.4

Comply

Provided

Material of cable clamp:

  1. Incomer/Link Disconnector

  2. Distance between cable clamp and neutral bar

  3. Outgoing/Fuse Switch Disconnector

  4. Distance between cable clamp and floor level

  5. ming and Outgoing clamps are alternately leveled

  6. No, of alternately leveled cable clamps:

    -Incomer Link Disconnector

    -Outgoing Fuse Switch Disconnector

Wood

Metal 

250mm

430mm

Comply

1

5

Wood

Metal 

250mm

430mm

Comply

1

8

Minimum clearance of live parts:

  1. Phase to Phase

  2. Phase to Earth

 

25mm

19mm

 

Details of Paintwork

 

Polyester Powder Coating
Nubuck Anti-Stick
Paint/Alkyd Resins

 